My Client2

Frames

  • Frame height generally 2440 – refer plans
  • All step out walls to have bulkheads i.e. not raked or supported on overhangs (L.Skinner 26.11.10)
  • Frames 90mm @ 600 cts only
  • Check beam locations due to slight variations in models if using an existing job
  • CSD’s = 2 x width + 60mm + pack stud in a 90mm frame 2160 H/H (C.Tadman)
  • Generally N2 wind loads if not noted on purchase order check with Mark Butler
  • Redcliffe model raised roof detail – Click here
  • Internal door head height 2100 including wet areas!
  • 35mm internal door jambs located 35mm off junctions (07.08.09)
  • External entry / L’dry / L’dry combo door head height 2120.
  • External entry doors with side lights to be 1320 or 1230 stud opening width. Check plans and ensure to scale. If unsure increase width & provide pack studs.
  • ASD’s as per manufacturers stud openings sizes.
  • Brace outside wet areas

Windows

  • Check on purchase order. Any discrepancies notify Mark Butler
  • Every job should have a window schedule
  • Where Southern Star windows are used provide 60mm to height and width on manufacturers sizes (L.Skinner 13/08/15)
  • For A & L windows 22.5 degree roof pitch and tiled roof the head height is 2190mm
  • Head height for 2740 high frames is 2175mm unless shown or noted otherwise.
  • Window head height  for jobs with northlight trusses (Kakadu Model) and 10-15 degree roof pitch with infill over windows is 2125mm unless shown or noted otherwise
  • Windows at drop-off unless shown otherwise
  • Work to brickwork
  • Notes
  • Shower Niche where indicated 400mm H x 400mm W with 1200mm sill. (M.Butler 23/07/21)
  • Not provided, no blocking etc at this stage

Trusses

  • 90mm top and bottom chords
  • 10mm Plasterboard direct (G.Westbrook19.05.06)
  • Generally N2 wind loads if not noted check with Mark Butler
  • Redcliffe model raised roof detail – Click here
  • All step out walls to have bulkheads i.e. not raked or supported on overhangs (L.Skinner 26.11.10)
  • Supply 90×35 MGP10 30/5.4 for bushfire attack 29+ when required. Do Not Cut Back Overhangs. (Ross M 26.02.15)
  • Metal fascia unless shown otherwise
  • Allow for A/C units in every job (25/08/21)
  • Allow for additional ceiling trimmers for change of direction
  • Supply Simpson Truss screws and Pryda wall screws in lieu of the existing triple grips and internal wall brackets

Final Check

  • Design single & double garage door beams for single dwellings.
  • HWD temporary props 100×75 (L.Skinner 22/03/2019)
  • 70×20 sill supports  
  • Allow for additional ceiling trimmers for change of direction
  • Supply 90×35 MGP10 30/5.4 for bushfire attack 29+ when required. Do Not Cut Back Overhangs. (Ross M 26.02.15)
  • Generally Tillings SJ300 @ 450 cts check plans
  • 19mm Yellow tongue flooring (M.Butler 12/02/19)
  • Possible request to quote posi joists
  • No wet area set downs on two storey jobs (M.Butler 12/02/19)
  • Supply 19mm Scyon for wet areas on two storey jobs (M.Butler 12/02/19)

Pricing

  • Every job is quoted individually

Quotes & Customer Service

  • No soffit linings or A/C sheeting
  • No Pergola Material
  • No Steel beams unless required in floor system – make a note in the quote
  • All else in line with specifications