{"id":80,"date":"2026-02-12T02:45:20","date_gmt":"2026-02-12T02:45:20","guid":{"rendered":"https:\/\/sadlernet.com\/?p=80"},"modified":"2026-02-19T03:12:24","modified_gmt":"2026-02-19T03:12:24","slug":"client3","status":"publish","type":"post","link":"https:\/\/wordpress.sadlernet.com\/?p=80","title":{"rendered":"Client3"},"content":{"rendered":"\n<p>Version 2.0 \u2013 As of 22\/09\/2025<\/p>\n\n\n\n<p>New Living Homes &amp; New Edge Homes Frame Specifications<\/p>\n\n\n\n<h1 class=\"wp-block-heading\">Frames<\/h1>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Work off Construction Plans only. Check for latest plans on the Masterton portal before<\/li>\n\n\n\n<li>detailing.<\/li>\n\n\n\n<li>N2 wind speed unless noted otherwise<\/li>\n\n\n\n<li>Garage \/ Hallway walls may be used as load bearing. Check plans and engineers.<\/li>\n\n\n\n<li>Lintels maximum 5mm deflection<\/li>\n\n\n\n<li>Where practical in height for Bulkhead framing (coffered ceilings) use I\u2010Joists<\/li>\n\n\n\n<li>Square set opening height = 2100mm unless noted otherwise<\/li>\n\n\n\n<li>Entry (Front &amp; Rear) door head height = 2120 unless noted otherwise<\/li>\n\n\n\n<li>Standard internal door height = 2120 including wet areas<\/li>\n\n\n\n<li>Version 2.0 \u2013 As of 22\/09\/2025<\/li>\n\n\n\n<li>Smart robe doors as per smart robe catalogue. For wet areas head height is 2180 or 2480<\/li>\n\n\n\n<li>and all 10mm wider<\/li>\n\n\n\n<li>Cavity sliding door height for all jobs = 2165, width = (2 x Door) + 10mm always in a 90mm Frame<\/li>\n\n\n\n<li>Mirror sliding door robes to be detailed as a full width bulkhead frame over at 2130mm<\/li>\n\n\n\n<li>No control joint studs<\/li>\n\n\n\n<li>Do not sheet brace over where the hot water service is to be installed<\/li>\n\n\n\n<li>Vanity studs to be detailed 300mm to both sides of centerline of vanity to avoid drainage<\/li>\n\n\n\n<li>All alfresco piers are solid brick<\/li>\n\n\n\n<li>All porch \/ patio piers conceal a timber post \u2013 unless noted or shown otherwise \u2013 temporary<\/li>\n\n\n\n<li>props only provided<\/li>\n\n\n\n<li>For Madison &amp; Vogue Fa\u00e7ade (Raised Roofs) \u2013 beams sit on the top plate; trusses run to the inside of the beams with hangers.\u00a0\u00a0<\/li>\n\n\n\n<li>For the Elara Fa\u00e7ade, the front entry beam is not to sit on the top plate<\/li>\n\n\n\n<li>Timber blocking to be built in to walls behind vanities for added strength to wall hung<\/li>\n\n\n\n<li>vanities. Blocking to be a single height row of 140 x 35mm pine to each stud bay behind the vanity (width shown on floor plan). Bottom of blocks to be 740mm from bottom of wall<\/li>\n\n\n\n<li>frame<\/li>\n\n\n\n<li>Supply all frame tie down material as required<\/li>\n\n\n\n<li>FC sheeting to first floor wet areas<\/li>\n\n\n\n<li>Supply additional blocking to garage doors. Blocking to consist of 190 x 45mm timber above<\/li>\n\n\n\n<li>the garage door. (Refer to Dynamic Door Service \u201cSite Supervisor Reference Sheet\u201d. Blocking<\/li>\n\n\n\n<li>to be shown on frame layouts.)<\/li>\n\n\n\n<li>Wall hung vanities to all bathrooms and powder rooms. The plumbing for the vanity waste is to run through the bottom plate. If we are unable to achieve this due to joists or beams, builder must be notified.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Windows<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Dowell \u2013 Sizes as per window schedule on plan \u2013 add necessary clearances. Any<\/li>\n<\/ul>\n\n\n\n<p>discrepancies with sizes, brickwork dimensions contact New Living Homes<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>No Steel at all, even if required for lintel or bulkhead. Contact New Living Homes<\/li>\n\n\n\n<li>Aluminium sliding door coded 2127 to be 1785 stud opening. Disregard 2650 width on window schedule, plans to be amended<\/li>\n\n\n\n<li>Aluminium sliding door head height = 2140<\/li>\n\n\n\n<li>Head height 2440 high framed tiled roofs (For windows at drop\u2010off)<\/li>\n\n\n\n<li>Overhang 600 \u2013 Pitch 25 \u2013 Head height = 2170<\/li>\n\n\n\n<li>Overhang 600 \u2013 Pitch 22.5 \u2013 Head height = 2195<\/li>\n\n\n\n<li>Overhang 600 \u2013 Pitch 20.5 \u2013 Head height = 2220<\/li>\n\n\n\n<li>Overhang 150 \u2013 Pitch 25, 22.5, 20.5 \u2013 Head height = 2215<\/li>\n\n\n\n<li>Head height for 2600 &amp; 2700 Frames = 2230 unless shown otherwise<\/li>\n\n\n\n<li>Version 2.0 \u2013 As of 22\/09\/2025<\/li>\n\n\n\n<li>Head height 2440 high frames sheet metal roofs (For windows at drop\u2010off)<\/li>\n\n\n\n<li>Overhang 600 \u2013 Pitch 25 \u2013 Head height = 2140<\/li>\n\n\n\n<li>Overhang 600 \u2013 Pitch 22.5 \u2013 Head height = 2165<\/li>\n\n\n\n<li>Overhang 600 \u2013 Pitch 20.5 \u2013 Head height = 2190<\/li>\n\n\n\n<li>Note: Add 10mm to window stud opening height<\/li>\n\n\n\n<li>Jobs with 300mm overhang with infill above windows; head height is to be as per normal<\/li>\n\n\n\n<li>drop\u2010off with 600mm overhang<\/li>\n\n\n\n<li>Notes:<\/li>\n\n\n\n<li>Bath checkout is 470mm U\/S B\/Plate 170 x 20 * Up\/Down *<\/li>\n\n\n\n<li>No other blocking<\/li>\n<\/ul>\n\n\n\n<h1 class=\"wp-block-heading\">Trusses<\/h1>\n\n\n\n<p>\uf0b7 Work off Construction Plans only. Check for latest plans before detailing<\/p>\n\n\n\n<p>\uf0b7 For Steel Builders shop drawings and marking plans, click here;<\/p>\n\n\n\n<p><a href=\"https:\/\/www.dropbox.com\/sh\/6fvk3nh3flne5bj.AACSyj5Ovj_BbQnHDJbTo2Ika?dl=0\">https:\/\/www.dropbox.com\/sh\/6fvk3nh3flne5bj.AACSyj5Ovj_BbQnHDJbTo2Ika?dl=0<\/a><\/p>\n\n\n\n<p>\uf0b7 N2 wind speed unless noted otherwise<\/p>\n\n\n\n<p>\uf0b7 Provide 600mm overhang for 250mm walls not 610mm<\/p>\n\n\n\n<p>\uf0b7 10mm direct plasterboard unless noted otherwise<\/p>\n\n\n\n<p>\uf0b7 Allow for A\/C units on all jobs<\/p>\n\n\n\n<p>\uf0b7 90mm Top &amp; Bottom chords<\/p>\n\n\n\n<p>\uf0b7 Supply a roof truss bracing layout<\/p>\n\n\n\n<p>\uf0b7 Allow for additional internal wall brackets over the normal calculation<\/p>\n\n\n\n<p>\uf0b7 Provide additional ceiling trimmers to the alfresco areas &amp; extra 20% for double storeys<\/p>\n\n\n\n<p>\uf0b7 For Madison &amp; Vogue Fa\u00e7ade (Raised roofs) \u2013 beams sit on the top plate; trusses run to the<\/p>\n\n\n\n<p>inside of the beams with hangers<\/p>\n\n\n\n<p>\uf0b7 For the Elara Model the front entry beam is not to sit on the top plate<\/p>\n\n\n\n<p>\uf0b7 Standard saddles to be used where possible; 1500, 2700, 3900, 5100 etc<\/p>\n\n\n\n<p>\uf0b7 No Steel at all, even if required for lintel or bulkhead. Contact New Living<\/p>\n\n\n\n<p>\uf0b7 Extra rafters for BAL rated jobs rather than structural fascia where required<\/p>\n\n\n\n<p>\uf0b7 Due to material used for eaves lining in bushfire zones no additional material is required to a<\/p>\n\n\n\n<p>BAL40 rating<\/p>\n\n\n\n<p>\uf0b7 New Edge \u2013 Vibe Fa\u00e7ade no tails on the garage trusses except for the front truss to create<\/p>\n\n\n\n<p>the barge<\/p>\n\n\n\n<p>\uf0b7 New Edge \u2013 Supply structural fascia to gable ends<\/p>\n\n\n\n<p>\uf0b7 Metal fascia<\/p>\n\n\n\n<p>Final Check<\/p>\n\n\n\n<p>\uf0b7 70&#215;20 Merch Grade sill supports<\/p>\n\n\n\n<p>\uf0b7 Garage \/ Hallway walls may be used as load bearing. Check plans and engineers<\/p>\n\n\n\n<p>Version 2.0 \u2013 As of 22\/09\/2025<\/p>\n\n\n\n<p>\uf0b7 NO exposed beams to Alfresco \u2013 unless shown otherwise<\/p>\n\n\n\n<p>\uf0b7 Garage beams = 170&#215;63 LVL or as per design<\/p>\n\n\n\n<p>\uf0b7 Steel beam setup over garage door openings Compi\u2010bar<\/p>\n\n\n\n<p>\uf0b7 HWD temporary props<\/p>\n\n\n\n<p>\uf0b7 Timber Fillets<\/p>\n\n\n\n<p>\uf0b7 Where shaft\u2010liner on Dual\/Ocs run between brick and frame supply a temp beam, props and<\/p>\n\n\n\n<p>plates, eg 170 x 58 LVL 1\/6.0, 100 x 75 3\/2.7, 90 x 45 P10 2\/5.4. Check plans for quantities<\/p>\n\n\n\n<p>and lengths<\/p>\n\n\n\n<p>\uf0b7 Provide Kitchen bulkheads where stated by builder \u2013 I\u2010Joist preferred<\/p>\n\n\n\n<p>\uf0b7 Temporary frame brace supply \u00bc.8 length per 6Lm of frame<\/p>\n\n\n\n<p>\uf0b7 Porch \/ Patio roofs that do not have a raised roof and show a T\u2010Beam supply 2\/140&#215;35 P10<\/p>\n\n\n\n<p>Temp Beams and a 70&#215;45 P10 plate<\/p>\n\n\n\n<p>\uf0b7 Allow for additional internal wall brackets over the normal calculation<\/p>\n\n\n\n<p>\uf0b7 Provide additional ceiling trimmers to the alfresco areas &amp; extra 20% for double storeys<\/p>\n\n\n\n<p>\uf0b7 Floor systems by Tillings<\/p>\n\n\n\n<p>\uf0b7 Due to material used for the eaves lining in bushfire zones no additional material is required<\/p>\n\n\n\n<p>to a BAL40 rating<\/p>\n\n\n\n<p>\uf0b7 Garage door openings that show a T\u2010Beam supply 2\/140&#215;35 P10 Temp Beams and a 90&#215;45<\/p>\n\n\n\n<p>P10 plate (Even when stated non\u2010structural)<\/p>\n\n\n\n<p>\uf0b7 Check steel locations on plans &amp; engineers any discrepancies check with New Living Homes<\/p>\n\n\n\n<p>\uf0b7 Do not supply battens for metal roofs<\/p>\n\n\n\n<p>\uf0b7 Do not supply any DAR Posts<\/p>\n\n\n\n<p>\uf0b7 Do not supply posts on brickwork<\/p>\n\n\n\n<p>\uf0b7 Do not supply posts to columns<\/p>\n\n\n\n<p>Pricing<\/p>\n\n\n\n<p>\uf0b7 Standard Models \u2013 Variations apply<\/p>\n\n\n\n<p>Quotes &amp; Customer Service<\/p>\n\n\n\n<p>\uf0b7 In line with specifications<\/p>\n\n\n\n<p>\uf0b7 New Edge \u2013 Vibe Fa\u00e7ade no tails on the garage trusses except for the front truss to create<\/p>\n\n\n\n<p>the barge<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Version 2.0 \u2013 As of 22\/09\/2025 New Living Homes &amp; New Edge Homes Frame Specifications Frames Windows discrepancies with sizes, brickwork dimensions contact New Living Homes Trusses \uf0b7 Work off Construction Plans only. Check for latest plans before detailing \uf0b7 For Steel Builders shop drawings and marking plans, click here; https:\/\/www.dropbox.com\/sh\/6fvk3nh3flne5bj.AACSyj5Ovj_BbQnHDJbTo2Ika?dl=0 \uf0b7 N2 wind speed [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[24,6],"tags":[],"class_list":["post-80","post","type-post","status-publish","format-standard","hentry","category-nsw","category-client-specification"],"_links":{"self":[{"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=\/wp\/v2\/posts\/80","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=80"}],"version-history":[{"count":2,"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=\/wp\/v2\/posts\/80\/revisions"}],"predecessor-version":[{"id":86,"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=\/wp\/v2\/posts\/80\/revisions\/86"}],"wp:attachment":[{"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=80"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=80"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=80"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}