{"id":1,"date":"2024-02-04T08:55:40","date_gmt":"2024-02-04T08:55:40","guid":{"rendered":"http:\/\/ssgrserver\/wordpress\/?p=1"},"modified":"2026-02-15T12:56:36","modified_gmt":"2026-02-15T12:56:36","slug":"masterton_homes","status":"publish","type":"post","link":"https:\/\/wordpress.sadlernet.com\/?p=1","title":{"rendered":"My Client1"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">My Client Specs<\/h2>\n\n\n<div class=\"wp-block-post-date__modified-date wp-block-post-date\"><time datetime=\"2026-02-15T12:56:36+00:00\">15 February 2026<\/time><\/div>\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading is-style-default\"><strong>Frames<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Work off Construction Plans only.<strong>C<\/strong>heck for latest plans on the Masterton portal before detailing.&nbsp;<\/li>\n\n\n\n<li>Check&nbsp;framing notes on plan and purchase order for job specifics&nbsp;<\/li>\n\n\n\n<li>Check steel locations on plans &amp; engineers any discrepancies check with Masterton Homes<\/li>\n\n\n\n<li>Supply full height F27 (HWD) studs loose for steel beam supports in line with engineers &#8211; note on layout! All other openings and beam pockets <strong>noted<\/strong> with HWD studs to be in frame.<\/li>\n\n\n\n<li><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Internal%20Load%20Bearing%20Walls.pdf\">Intended internal load bearing walls as designated by Masterton<\/a> &#8211; MUST correlate with engineers details &#8211; confirm as required.<\/li>\n\n\n\n<li>Provide beam pockets to support timber beams in garage as required &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Beam%20Pockets%20Garage.pdf\">Click here for details<\/a><\/li>\n\n\n\n<li>Frame heights as per plan&nbsp;<\/li>\n\n\n\n<li>Studs @ 450cts to wet areas &#8211; brace outside wet areas<\/li>\n\n\n\n<li><strong>No Steel at all, <\/strong>even if required for lintel or bulkhead. Contact Masterton. (Trish 23\/05\/03)<\/li>\n\n\n\n<li>Any steel required that is not noted on the engineers details, Masterton draughting department must be notified. <strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/MASTextrasteel.xls\">This form<\/a><\/strong> must be filled out and emailed to <a href=\"mailto:clint.masterton@masterton.com.au\">clint.masterton@masterton.com.au <\/a>at detailing stage. Provide a brief description of where the steel is required. (19\/11\/14)<\/li>\n\n\n\n<li>All columns and pedestals to be in pre-fab frame.&nbsp;<\/li>\n\n\n\n<li>Where practical in height for Bulkheads&nbsp;(coffered ceilings) use I-Joists or pre-fab if I-Joist unavailable.&nbsp;(S.Jackman 23\/01\/09)<\/li>\n\n\n\n<li>Kitchen bulkheads if requested &nbsp;&#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/KITCHEN%20BULKHEADS.PDF\">Click here for details<\/a> (30\/04\/13)<\/li>\n\n\n\n<li>240mm deep bulkheads to kitchens make 200mm deep (S.McClean 14\/12\/20)<\/li>\n\n\n\n<li>Delta Model splits to have 1 high wall instead of 2 short walls (21\/3\/02)<\/li>\n\n\n\n<li>Party Wall Construction <strong>&#8211;&nbsp;<\/strong>Usually Boral Partiwall shaftliner<\/li>\n\n\n\n<li>Party Wall Construction for single storey running into double story run trusses parallel to the party wall or refer to Masterton homes for information or details.<\/li>\n\n\n\n<li>Wind speed noted on plan<\/li>\n\n\n\n<li>Beam Details <strong>&#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/Masterton%20Beam%20Details.htm\">Click here for all Masterton Beam Details<\/a><\/strong><\/li>\n\n\n\n<li>Dual Occupancy Alfresco detail with masonry partiwall &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/Masterton%20Specs_files\/Partiwall.pdf\">Click here<\/a><\/li>\n\n\n\n<li><strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/masterton%20portico%20beam.JPG\">Click here for the Horizon Portico beam detail<\/a><\/strong><\/li>\n\n\n\n<li><strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Horizon%20Elite%20Alcove%20Detail.jpg\">Click here for Horizon Elite Alcove Detail (Detail A)<\/a> and <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Horizon%20Elite%20Stair%20Details.pdf\">Stair details<\/a> &#8211; refer to plans for any variations<\/strong><\/li>\n\n\n\n<li><strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Masterton%20Balcony%20Detail.pdf\">Click here for Balcony Joists Detail<\/a><\/strong><\/li>\n\n\n\n<li>Centre the front entry door&nbsp;between the brick work on&nbsp;SIROCCO models, except the Santa Fe Facade (Trish 7\/3\/3)<\/li>\n\n\n\n<li>Standard External (Front &amp; Rear) and Internal door heights 2130 or 2430 including where timber&nbsp;flooring is used and wet areas (12\/05\/11)<\/li>\n\n\n\n<li>Aluminium Sliding Door Head Height = 2140<\/li>\n\n\n\n<li>Cavity Sliding Door Height for all Jobs = 2165,&nbsp; Width = (2 x Door)&nbsp;+ 10mm (S.Jackman 09\/08\/06) in 90mm Frame (S.Wilson 01\/12\/08)<\/li>\n\n\n\n<li>Smart Robe doors head height in wet areas 2180 or 2480 &#8211; refer plans (12\/05\/11)<\/li>\n\n\n\n<li>Smart Robe doors make the openings 10mm wider than what is on plan (S.Jackman 4\/9\/06)<\/li>\n\n\n\n<li>Be aware that on some models on the upper floor around the stairwell a 90mm frame is generally used &#8211; check the plans!<\/li>\n\n\n\n<li>Two storey models with stairwell windows where a wind beam is not used ensure jamb studs are placed in the ground floor frame so they appear continuos from the upper floor frame &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Stairwell%20Window.JPG\">Click here<\/a><\/li>\n\n\n\n<li><strong>Harmony<\/strong> models that have a raked ceiling in the Kitchen and dutch gable over the Alfresco; Do NOT place the gable truss over the wall; place outside and provide gable battens as the frame will not be raked (25\/03\/19) &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Harmony.pdf\"><strong>Click here for details<\/strong><\/a><\/li>\n\n\n\n<li><strong>Villina<\/strong> model raked wall elevations to stairs &#8211; Check plans for any differances &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Villina%20Raked%20Wall%20Elevation.pdf\">Click here for details<\/a><\/li>\n\n\n\n<li><strong>Willow<\/strong> (Duplex) Models &#8211; <strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Willow%20Stair%20Detail.pdf\">Click here for Memo and Stair Details<\/a><\/strong><\/li>\n\n\n\n<li><strong>Accent <\/strong>models to have a 250 x 45 floor beam detailed over the stair square set with joist hangers to replace load&nbsp; bearing frame &#8211; <strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Accent%20Floor%20Beam.jpg\">Click here for details<\/a><\/strong><\/li>\n\n\n\n<li>Masterton have made amendments to the Accent stair dimensions. They have also requested that we detail critical studs in the upper handrail wall to accommodate the balustrade &#8211; <strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Masterton%20accent%20stair%20detail.JPG\">Click here for detail<\/a><\/strong>&nbsp;&nbsp; (Print to A3 printer)<\/li>\n\n\n\n<li>McAlister model steel requirements &#8211; <strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Steel%20image.jpg\">Click here for details<\/a><\/strong><\/li>\n\n\n\n<li>Details for Masterton Jamison model (Refer to plans for dimensions) &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Jamison%20Model%201.JPG\">Example Jamison Model 1<\/a> &amp;&nbsp;<strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Jamison%20Model%202.JPG\">Example&nbsp;Jamison Model 2&nbsp;<\/a><\/strong>(Supply 140&#215;45 F5 H3 1\/4.8, 2\/5.4) &#8211; Tillings must not supply!<\/li>\n\n\n\n<li>Mayfair, Santorini and Jamison Models and others to which it applies no beam in floor system over square sets due to problems with A\/C ducting lintel to be in the square set &#8211; <strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/AC%20Problems.pdf\">Click here for Detail<\/a><\/strong><\/li>\n\n\n\n<li>Delta Porch Beam Setup &#8211; <strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Delta%20Porch%20Beam.jpg\">Click here for details<\/a><\/strong> &#8211; (Trish 21\/3\/03)<\/li>\n\n\n\n<li>Sirocco models and those similar with porch piers that have a double post on it supply a beam across the front, as the side beams do not sit on the posts. Also supply 2xTBJ70 hangers to pick up the side beams.<\/li>\n\n\n\n<li>Square set opening heights for 2440 &amp; 2600 high frames generally 2100. For 2700&nbsp;high frames generally 2340 &#8211; Unless noted otherwise.<\/li>\n\n\n\n<li>Doors &#8211; D5=520 &#8211; D6=620 &#8211; D7=720 &#8211; D8=820 &#8211; D9=770 &#8211; D7CSD=720 &#8211; D8CSD=820 &#8211; D9CSD=770 &#8211; refer to schedule (check heights!)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Windows<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Windows<\/li>\n\n\n\n<li>Dowell &#8211; Refer to purchase order!<strong> <\/strong>Sizes as per window schedule on plan &#8211; add necessary clearances.&nbsp;<\/li>\n\n\n\n<li>Maximum lintel deflection (or similar) 6mm.<\/li>\n\n\n\n<li>Ensure the window schedule on plan matches the brickwork dimensions &#8211; confirm discrepancies with Masterton.<\/li>\n\n\n\n<li>Provide pack studs with no additional width and a loose head trimmer or double trimmer dependant on window head height &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Window%20Packing.pdf\">Click here<\/a> (12\/02\/21)<\/li>\n\n\n\n<li>Square set windows shown hard up against the frame are to go into the junction 35mm &#8211; usually stairwell windows.<\/li>\n\n\n\n<li>McArthur Manor jobs usually use Advantage windows &#8211; check with purchase order! (D.Bradshaw 27.01.10&nbsp;)<\/li>\n\n\n\n<li>Cafe window details &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Cafe%20Windows.pdf\">Click here<\/a>. Any discrepancies contact Masterton Homes.<\/li>\n\n\n\n<li>Check for Kitchen window nominated sill height!<\/li>\n\n\n\n<li>Maintain 600mm overhang to 250mm not 610mm (J.Hill \/ P.Summer 05\/07\/05)<\/li>\n\n\n\n<li>Corner windows to be completely supplied by frame detailer &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<\/li>\n\n\n\n<li>Head Height&nbsp;<strong>2440<\/strong> High Frames&nbsp;Tiled Roofs (For Windows at drop-off) (L.Pitman 14.07.10)<\/li>\n\n\n\n<li>Overhang 600 &#8211; Pitch 25 &#8211; Head Height = 2170<\/li>\n\n\n\n<li>Overhang 600 &#8211; Pitch 22.5 &#8211; Head Height = 2195<\/li>\n\n\n\n<li>Overhang 600 &#8211; Pitch 20.5 &#8211; Head Height = 2220&nbsp;&nbsp;&nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<\/li>\n\n\n\n<li>Overhang 150 &#8211; Pitch 25, 22.5, 20.5 &#8211; Head Height <strong>2215<\/strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<\/li>\n\n\n\n<li>Head Height for 2600 &amp; 2700 Frames = <strong>2230 <\/strong>unless shown otherwise (L.Pitman 18.07.11)&nbsp; &nbsp; &nbsp;&nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<br><\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Head Height&nbsp;<strong>2440<\/strong> High Frames&nbsp;Sheet Metal Roofs (For Windows at drop-off) (L.Pitman 14.07.10)<\/li>\n\n\n\n<li>Overhang 600 &#8211; Pitch 25 &#8211; Head Height = 2140<\/li>\n\n\n\n<li>Overhang 600 &#8211; Pitch 22.5 &#8211; Head Height = 2165<\/li>\n\n\n\n<li>Overhang 600 &#8211; Pitch 20.5 &#8211; Head Height = 2190<\/li>\n\n\n\n<li>Note : <strong>Add 10mm to window stud opening height only where windows are at drop off!<\/strong><\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Notes<\/strong><\/li>\n\n\n\n<li>Bath and Spa Checkout is 490mm U\/S B\/Plate 150&#215;20 * Up\/Down * <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Masterton%20BathSpa%20Checkout.jpg\"><strong>Click here for detail<\/strong>.<\/a> (S.Jackman 24\/06\/05)<\/li>\n\n\n\n<li>Supply bath hobbs to Chisholm lodge and Mcarthur manor models only usually 590mm high &#8211; refer to plans<\/li>\n\n\n\n<li>Wet Area noggs 2 x rows at 1200 or 1350mm based on frame height to C\/L from U\/S B\/Plate (Exclude Laundry) (Trish 20\/06\/03) &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Wet%20Area%20Detail.pdf\">Click here for Detail<\/a><\/li>\n\n\n\n<li>140mm blocking on B\/Plate for shower recesses &#8211; include dwarf walls to the shower<\/li>\n\n\n\n<li>Double studs to all showers for fixing<\/li>\n\n\n\n<li>Minimum niche size to showers 400mm x 400mm @ 1100mm from floor &#8211; refer detail sheets<\/li>\n\n\n\n<li>Provide I-Joist material (300&#215;42) for Vanities 300mm high 190mm in depth 200mm narrower than vanity length if free standing 100mm if against a wall or pre-fab if I-Joist unavaible (L.Wise 13\/06\/17) &#8211;&nbsp;<a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/FLOATING%20VANITY%20DETAILS.013.pdf\"><strong>Click here<\/strong><\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Trusses<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Work off Construction Plans only<\/strong>.Check for latest plans before detailing.<\/li>\n\n\n\n<li>Ensure disclaimer is noted for NON STRUCTRUAL FASCIA on the layout supplied to site and the computations. (Trish 13\/12\/11)<\/li>\n\n\n\n<li>Check the framing notes on plan for job specifics&nbsp;<\/li>\n\n\n\n<li>Check steel locations on plans &amp; engineers any discrepancies check with Masterton Homes<\/li>\n\n\n\n<li>Refer to engineers for any specific requirements over stacker doors<\/li>\n\n\n\n<li><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Internal%20Load%20Bearing%20Walls.pdf\">Intended internal load bearing walls as designated by Masterton<\/a> &#8211; MUST correlate with engineers details &#8211; confirm&nbsp;as required.<\/li>\n\n\n\n<li>Provide 600mm overhang for 250mm walls not 610mm (J.Hill \/ P.Summer 05\/07\/05)<\/li>\n\n\n\n<li>TG stations to be 2400 on 20.5 &amp; 22.5 deg roof, concrete &amp; terracotta tiles<\/li>\n\n\n\n<li>Party Wall Construction <strong>&#8211;&nbsp;<\/strong>Usually Boral Partiwall shaftliner<\/li>\n\n\n\n<li>For Timber Party walls where girders run&nbsp;into the ledger plate with greater than a 4kn dead load it must be refered to Pryda to provide fixing details.<br><\/li>\n\n\n\n<li>Party Wall Construction for single storey running into double story run trusses parallel to the party wall or refer to Masterton homes for information or details.<\/li>\n\n\n\n<li>Dual Occupancy Alfresco detail with masonry partiwall &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/Masterton%20Specs_files\/Partiwall.pdf\">Click here<\/a><\/li>\n\n\n\n<li><strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/masterton%20half%20dutch%20gable%20sirocco.JPG\">Click here for the Sirocco Federation cut off Dutch Hip Girder detail<\/a><\/strong><\/li>\n\n\n\n<li><strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/masterton%20portico%20beam.JPG\">Click here for the Horizon Portico beam detail<\/a><\/strong><\/li>\n\n\n\n<li><strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/masterton%20small%20gable%20sirocco.JPG\">Click here for the Sirocco, Horizon, Jamison etc small gable detail<\/a><\/strong><\/li>\n\n\n\n<li><strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/masterton%20Sirocco%20raised%20roof.JPG\">Click here for the Sirocco Santa Fe raised roof detail<\/a><\/strong><\/li>\n\n\n\n<li><strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Chisolm%20Lodge%20Detail.jpg\">Click here for the Chisolm Lodge Detail<\/a><\/strong><\/li>\n\n\n\n<li>Wind speed noted on plan<\/li>\n\n\n\n<li>90mm Top &amp; Bottom Chords<\/li>\n\n\n\n<li>Box gutters minimum 220W x 150H &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Box%20Gutter.pdf\">Click here<\/a><\/li>\n\n\n\n<li>Valley box gutter detail for metal roofs under 12.5 degrees or lower &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Box%20Valley.pdf\">Click here<\/a> (12\/02\/21)<\/li>\n\n\n\n<li>For truss spans under 10.0M accommodate for these <strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/LG%20AC.pdf\">A\/C Units<\/a><\/strong> and <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/AC%20Units%20Under%2010M.pdf\">as per this detail<\/a> weight 100kg; minimum clearance 1500W x 2400L x 700H (M.Milne 3.11.06)<\/li>\n\n\n\n<li><strong>McArthur Manor<\/strong> models &#8211; accommodate for A\/C units <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/M1%20version2.pdf\"><strong>as per this detail<\/strong><\/a> (M.Milne)<\/li>\n\n\n\n<li><strong>Harmony<\/strong> models that have a raked ceiling in the Kitchen and dutch gable over the Alfresco; Do NOT place the gable truss over the wall; place outside and provide gable battens as the frame will not be raked (25\/03\/19) &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Harmony.pdf\"><strong>Click here for details<\/strong><\/a><\/li>\n\n\n\n<li>Metal Fascia<\/li>\n\n\n\n<li>Trussed hip ends (S.Jackman 24\/06\/05)<\/li>\n\n\n\n<li>For overhangs greater than 450mm place &#8220;S&#8221; for hip support on the layout &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Hip%20Support.jpg\">Click here for detail<\/a><\/li>\n\n\n\n<li>Supply a roof truss bracing layout&nbsp;<\/li>\n\n\n\n<li>Bal 29 requirement &#8211; trusses to be cut back 35mm &amp; 90 x 35 P10 Perimeter plate supplied loose<\/li>\n\n\n\n<li>Gables, standard and dutch to have pre-cut verge rafters, outriggers and setdown truss. No gunstock outriggers.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Final Check<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Supply beams to all portico roofs (21\/3\/02)<\/li>\n\n\n\n<li>Supply full height F27 (HWD) studs loose for steel beam supports in line with engineers &#8211; note on layout! All other openings and beam pockets <strong>noted<\/strong> with HWD studs to be in frame.<\/li>\n\n\n\n<li>Supply 12mm x 100mm AnkaScrew (21002770) for &#8220;B-TYPE&#8221; bracing and washers 50x50x3.0 (BNWPS503)<\/li>\n\n\n\n<li>Skirting blocks to be supplied loose 90&#215;35 or 70&#215;35 F4 H2 Blue based on frame depth. 440mm lengths for 590cts and 300mm lengths for 450cts. (C.Masterton 12\/04\/17)<\/li>\n\n\n\n<li>Supply 10 x additional spare studs which includes extra for control joint studs (C.Masterton 12\/04\/17)<\/li>\n\n\n\n<li>Temp frame brace supply 1\/4.8 length per 3LM of frame in lieu of previous 5LM<\/li>\n\n\n\n<li>Do not supply any DAR Posts. Do not supply posts on brickwork, Do not supply posts to columns (Trish 13\/12\/11)<\/li>\n\n\n\n<li>Macarthur Model supply 30\/6.0 90&#215;35 P10 &amp; 4 sheets of 17mm CD Ply for curved walls, plates etc.<\/li>\n\n\n\n<li>Jamison Model &#8211; supply 140&#215;45 F5 H3 1\/4.8, 2\/5.4 for Stairwell joists &amp; trimming<\/li>\n\n\n\n<li>Supply 140x35P10 2\/6.0 to garage steel beams for packing to support trusses (5\/2\/03 Trish) &#8211;&nbsp;150 LVL15 for spans exceeding 6.0M.&nbsp;<\/li>\n\n\n\n<li>Garage Beams = 170&#215;63 LVL or as per design<\/li>\n\n\n\n<li>Steel beam setup over garage door openings Compi-bar &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/D-DO-003%20%28A%29-GARAGE%20DOORS%20-%20COMPI-BAR%20DETAIL_190918.pdf\">Click here<\/a><\/li>\n\n\n\n<li>Case Grade DAR 75&#215;25 Window support battens to all windows<\/li>\n\n\n\n<li><strong>No Steel at all, <\/strong>even if required for lintel or bulkhead. Contact Masterton. (Trish 23\/05\/03)<\/li>\n\n\n\n<li>Any steel required that is not noted on the engineers details, Masterton draughting department must be notified. <strong><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/MASTextrasteel.xls\">This form<\/a><\/strong> must be filled out and emailed to <a href=\"mailto:clint.masterton@masterton.com.au\">clint.masterton@masterton.com.au<\/a> at detailing stage. Provide a brief description of where the steel is required.<\/li>\n\n\n\n<li>All steel by builder<\/li>\n\n\n\n<li>Temp truss brace, <strong>No<\/strong> saddle restraints,<\/li>\n\n\n\n<li>Ceiling Trimmers supply enough&nbsp;including change of direction &#8211; provide&nbsp;an additional 100 ceiling trimmers for all&nbsp;jobs<\/li>\n\n\n\n<li>Supply truss spacers (GTSPACER6)<\/li>\n\n\n\n<li>100&#215;25 Case Grade valley board &#8211; supply an extra length 1\/6.0 (P.Wright 18\/6\/11)<\/li>\n\n\n\n<li>HWD Temporary Props (up to 3.0M) for supporting temp garage beams only. Do not supply for Porch \\ Patio or Alfresco&#8217;s (C.Masterton 12\/04\/17)<\/li>\n\n\n\n<li>Temp props over 3.0M provide sufficient Case Grade Temp Props so they can be doubled up (C.Doppler 06\/02\/13)<\/li>\n\n\n\n<li>Alfresco Beams&nbsp;360&#215;65 GL10 or 360 17C as per design.&nbsp;If not marked on plans ring Draughting department and confirm, also advise if beam design fails and steel is required! (L.Pitman 21\/05\/2012)<\/li>\n\n\n\n<li>For Bal 29 and over Alfresco beams can be 360 LVL&#8217;s by design and are to be lined (fireproofed) by Masterton &#8211; note on layout.&nbsp;<\/li>\n\n\n\n<li>Do not supply battens for metal roofs<\/li>\n\n\n\n<li>Do not supply ceiling trimmers to verandahs or patios (3\/2\/03 Trish)<\/li>\n\n\n\n<li>Sirocco models and those similar with porch piers that have a double post on it supply a beam across the front, as the side beams do not sit on the posts. Also supply 2xTBJ70 hangers to pick up the side beams.<\/li>\n\n\n\n<li>Check steel locations on plans &amp; engineers any discrepancies check with Masterton Homes<\/li>\n\n\n\n<li>Floor System Tillings I Beams 300&#8217;s @ 600c\/s (10.8.12 G Mercer) with floor adhesive (Selleys &#8211; Prostix Code 43002010)&nbsp;(2.2.2012 P Summer)<\/li>\n\n\n\n<li>22mm treated flooring regardless of floor joist spacing&nbsp;<\/li>\n\n\n\n<li>Floor joists to be spaced @ 450cts to wet areas<\/li>\n\n\n\n<li>Additonal floor joists required to hallways for ground floor fixing of light fixtures centrally. Avoid locating joists to the centre;&nbsp;joists to be offset &#8211; <a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/Masterton%20Specs_files\/Floor%20Joist%20Hallway.JPG\">Click here<\/a><strong>.<\/strong><\/li>\n\n\n\n<li>Provide continuous end blocking&nbsp;to the perimeter for exterior load bearing walls<\/li>\n\n\n\n<li>Joists run into steel without hangers. Allow 90&#215;35 P10 for blocking (the length of the steel)<br><\/li>\n\n\n\n<li>Allow web stiffeners to joist that are larger than steel beam<\/li>\n\n\n\n<li>All&nbsp;balcony material for Masterton Homes is to be H3 treated (Steve Jackman 26.2.07)<\/li>\n\n\n\n<li>Balcony joists H3 190&#215;45 F7 (Check floor system depth) &#8211; Balcony Joists layouts are required to be sent to site<\/li>\n\n\n\n<li>All <strong>Horizon<\/strong> models have timber fillet studs to the pantry, prostix code RFS075050<\/li>\n\n\n\n<li>Allow 100&#215;25 Case 2 off to steel in bulkheads<\/li>\n\n\n\n<li><strong>Balcony flooring &#8211;&nbsp;<\/strong>James Hardie&#8217;s Scyon&nbsp;&amp;&nbsp;James Hardie&#8217;s Joint Sealer&nbsp;<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Quotes &amp; Customer Service<\/strong><\/h2>\n\n\n\n<p><a href=\"file:\/\/\/C:\/Users\/shane\/SynologyDrive\/desktop\/Pryda%20Bunnings\/Bunnings%20Web\/MastertonPL\/Internal%20Load%20Bearing%20Walls.pdf\">Intended internal load bearing walls as designated by Masterton<\/a> &#8211; MUST correlate with engineers details &#8211; confirm as required.<\/p>\n\n\n\n<p>Inline with specifications<\/p>\n\n\n\n<p>A disclaimer is to be noted for NON STRUCTRUAL FASCIA on the quote, layout supplied to site and the computations. (Trish 13\/12\/11)<\/p>\n\n\n\n<p><strong>Council Comps<\/strong> &#8211; send truss layout, frame bracing layout and details, full set of abbreviated computations.<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>My Client Specs Frames Windows Trusses Final Check Quotes &amp; Customer Service Intended internal load bearing walls as designated by Masterton &#8211; MUST correlate with engineers details &#8211; confirm as required. Inline with specifications A disclaimer is to be noted for NON STRUCTRUAL FASCIA on the quote, layout supplied to site and the computations. (Trish [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6,26],"tags":[12],"class_list":["post-1","post","type-post","status-publish","format-standard","hentry","category-client-specification","category-client-specification-qld","tag-client-specifications"],"_links":{"self":[{"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=\/wp\/v2\/posts\/1","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1"}],"version-history":[{"count":3,"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=\/wp\/v2\/posts\/1\/revisions"}],"predecessor-version":[{"id":79,"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=\/wp\/v2\/posts\/1\/revisions\/79"}],"wp:attachment":[{"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wordpress.sadlernet.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}